Rigid bronchoscopy recipe

Full monitoring

IVI + arterial line

Pre-O2

Propofol & remi TIVA induction -> maintenance

(or remi in mcg/kg/min or ml/hr)

[Check ventilation]

Paralyse

Insert ventilating bronchoscope. Attach Sanders Jet Ventilator. Beware of loose connection, kinks in tubing

Jet ventilate 10-12 bpm. Allow expiration

Pause as needed e.g. laser

Suction + Insert LMA

Wake-up