Tag Archives: Airtraq

Airtraq tips

In a situation where the view is good but difficulty is encountered passed ETT between the cords consider the following:

Manoeuvring Airtraq (+/- head/airway) e.g. ‘drop’ it into pharynx to align angles better

Positioning of the glottis ‘target’ towards bottom right of screen

Use of bougie or wide bore NG tube (with ETT railroaded)

Alternative ETT e.g. standard instead of RAE